Atendimento ao Cliente da Divisão de Sensores Industriais
Rede de Atendimento - Divisão de Proteção Contra Explosão

Temperature Converter with Trip Values KFD2-GUT-Ex1.D

KFD2-GUT-Ex1.D
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Thermocouple, RTD, potentiometer or voltage input
  • Redundant TC input
  • Current output 0/4 mA ... 20 mA
  • 2 relay contact outputs
  • Configurable by PACTware or keypad
  • Line fault (LFD) and sensor burnout detection
  • Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Folhas de dados: Dados técnicos do  KFD2-GUT-Ex1.D

General specifications
Signal typeAnalog input
Functional safety related parameters
Safety Integrity Level (SIL)SIL 2
Supply
Connectionterminals 23+, 24- or power feed module/Power Rail
Rated voltage20 ... 30 V DC
Rated currentapprox. 100 mA
Power dissipation/power consumption≤ 2 W / 2.2 W
Interface
Programming interfaceprogramming socket
Input
Connection sidefield side
Connectionterminals 1, 2, 3, 4, 6
RTDPt100, Pt500, Pt1000, Ni100, Ni1000
Types of measuring2-, 3-, 4-wire technology
Lead resistancemax. 50 Ω
Measurement loop monitoringsensor breakage, sensor short-circuit
Thermocouplestype B, E, J, K, L, N, R, S, T (IEC 584-1: 1995)
Cold junction compensationexternal and internal
Measurement loop monitoringsensor breakage
Potentiometer0.8 ... 20 kΩ
Types of measuring2-, 3-, 5-wire technology
Voltage0 ... 10 V , 2 ... 10 V , 0 ... 1 V , -100 ... 100 mV
Input resistance≥ 250 kΩ (0 ... 10 V)
min. 1 MΩ (0 ... 1 V, -100 ... 100 mV)
Measuring currentapprox. 400 µA with resistance measuring sensor
Output
Connection sidecontrol side
Connectionoutput I: terminals 10, 11, 12
output II: terminals 16, 17, 18
output III: terminals 8+, 7-
Output I, IIrelay
Contact loading250 V AC / 2 A / cos φ ≥ 0.7 ; 40 DC / 2 A
Mechanical life5 x 107 switching cycles
Energized/De-energized delayapprox. 20 ms / approx. 20 ms
Output IIIAnalog current output
Current range0 ... 20 mA or 4 ... 20 mA
Open loop voltagemax. 24 V DC
Loadmax. 650 Ω
Fault signaldownscale I ≤ 3.6 mA, upscale I ≥ 21 mA (acc. NAMUR NE43)
Collective error messagePower Rail
Transfer characteristics
Deviation
Temperature effect Input: 0.005 %/K (50 ppm) of span ; current output: 0.005 %/K (50 ppm) of span
RTDmax. 0.2 % of span
Thermocouplesmax. 10µV
deviation of CJC: ±0.8 K
Voltage0.1 % of span
Potentiometer0.1 % of span when < 5 kΩ
0.5 % of span when > 5 kΩ
Current outputmax. 20 µA
Sampling rateapprox. 700 ms
Galvanic isolation
Input/Other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I, II against eachotherreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I, II/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output III/power supply and collective errorreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Interface/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Indicators/settings
Display elementsLEDs , display
Control elementsControl panel
Configurationvia operating buttons
via PACTware
Labelingspace for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Low voltage
Directive 2014/35/EUEN 61010-1:2010
Conformity
Electromagnetic compatibilityNE 21:2007
Degree of protectionIEC 60529:2001
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protectionIP20
Connectionscrew terminals
Mass300 g
Dimensions40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2
Height119 mm
Width40 mm
Depth115 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
EU-type examination certificateTÜV 03 ATEX 2140
MarkingEx-Hexagon II (1)G [Ex ia Ga] IIC
Ex-Hexagon II (1)D [Ex ia Da] IIIC
Ex-Hexagon I (M1) [Ex ia Ma] I
InputEx ia
Supply
Maximum safe voltage40 V DC (Attention! The rated voltage can be lower.)
Inputterminals 2, 6 (for active equipment)
Voltage13.1 V
Current8 mA
Power67 mW
Voltage29 V
Current11 mA
Power200 mW
Inputsterminals 1, 2, 3, 4, 6 (for passive equipment)
Voltage Uo13.1 V
Current Io21 mA
Power Po67 mW
Analog output
Maximum safe voltage40 V (Attention! The rated voltage can be lower.)
Interface
Maximum safe voltage40 V (Attention! The rated voltage can be lower.) , RS 232
CertificatePF 08 CERT 1213 X
MarkingEx-Hexagon II 3G Ex nA nC IIC T4 Gc
Output I, II
Contact loading50 V AC/2 A/cos φ > 0.7; 40 V DC/1 A resistive load
Galvanic isolation
Input/Other circuitssafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
IECEx approval
IECEx certificateIECEx TUN 09.0019
IECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I
General information
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027210129
ECLASS 12.027210129
ECLASS 11.027210129
ECLASS 10.0.127210129
ECLASS 9.027210129
ECLASS 8.027210190
ECLASS 5.127210107
ETIM 9.0EC002919
ETIM 8.0EC002919
ETIM 7.0EC002919
ETIM 6.0EC002919
ETIM 5.0EC001485
UNSPSC 12.132101514

Details: KFD2-GUT-Ex1.D

Datasheet: KFD2-GUT-Ex1.D

DatasheetTipo de ArquivoTamanho do Arquivo
Datasheet KFD2-GUT-Ex1.DPDF1449 KB
Fiche de données KFD2-GUT-Ex1.DPDF1456 KB
Datenblatt KFD2-GUT-Ex1.DPDF1451 KB
Datasheet KFD2-GUT-Ex1.DPDF1497 KB
Hoja de datos KFD2-GUT-Ex1.DPDF1458 KB

Documents: KFD2-GUT-Ex1.D

ManualsTipo de ArquivoTamanho do Arquivo
ManualPDF3685 KB
Manual KF**-GUT-(Ex)1.DPDF1709 KB
Manual KF**-GUT-(Ex)1.DPDF2570 KB
HandbuchPDF3693 KB
Handbuch KF**-GUT-(Ex)1.DPDF2282 KB
Instruction leaflets
Operator card KF**-GUT-**1.D / Bedienkarte KF**-GUT-**1.DPDF348 KB
Instruction manuals
ИнструкцииPDF172 KB
Instruction manual / BetriebsanleitungPDF328 KB
Návod k poużitíPDF166 KB
Instruktions manualPDF166 KB
Instruction manualPDF175 KB
KasutusjuhendPDF160 KB
KäyttöohjePDF160 KB
Manuel d'instructionsPDF168 KB
BetriebsanleitungPDF172 KB
Οδηγίες χρήσηςPDF175 KB
HandleidingPDF167 KB
Instruction manual / BetriebsanleitungPDF164 KB
Használati útmutatóPDF167 KB
Manuale di istruzioniPDF166 KB
Lietošanas pamācībaPDF165 KB
Instrukciju vadovasPDF165 KB
Instrukcja obsługiPDF168 KB
Manual de instruçõesPDF167 KB
Manual de utilizarePDF166 KB
Návod na poużitiePDF166 KB
Navodila za uporaboPDF164 KB
Manual de instruccionesPDF167 KB
ManualPDF162 KB
Application reports
Application Report - Biological Cleaning of Wastwater and Secondary Sedimentation StagePDF566 KB
Application Report - Energy Generation in Wastwater Treatment PlantsPDF532 KB
Application Report - Generating Electricity in Coal-Fired Power PlantsPDF412 KB
Application Report - Intelligent und Efficient: Temperature Measurement with Trip AmplifiersPDF285 KB
Application Report - Sand Trap and Preliminary Sedimentation StagePDF448 KB
Application Report - Screening Systems in Sewage Treatment PlantsPDF577 KB
Application Report - Sicherer Brennstofftransport in KohlekraftwerkenPDF391 KB
Application Report - Temperature Converter Detects Limit ValuesPDF348 KB
Application Report - Water Inlet in Wastewater Treatment PlantsPDF526 KB
Applikationsbericht - Biologische Abwasserreinigung und NachklärungPDF568 KB
Applikationsbericht - Energiegewinnung in KläranlagenPDF535 KB
Applikationsbericht - Intelligent und effizient: Temperaturmessung mit GrenzwertschalternPDF289 KB
Applikationsbericht - Rechenanlagen in KläranlagenPDF578 KB
Applikationsbericht - Sandfang und VorklärungPDF434 KB
Applikationsbericht - Sicherer Brennstofftransport in KohlekraftwerkenPDF393 KB
Applikationsbericht - Stromerzeugung in KohlekraftwerkenPDF416 KB
Applikationsbericht - Temperaturmessumformer erkennt GrenzwertePDF352 KB
Applikationsbericht - Wasserzulauf in KläranlagenPDF527 KB
Documents
Installation and configuration guide Device Type Manager (DTM)PDF8665 KB
Installations- und Konfigurationsanleitung Device Type Manager (DTM)PDF8463 KB

CAD+CAE: KFD2-GUT-Ex1.D

CADTipo de ArquivoTamanho do Arquivo
CAD 3-D / CAD 3-DSTP2720 KB
CAD Portal / CAD PortalLINK---
EPLAN
CAE EPLAN Data Portal / CAE EPLAN Data PortalLINK---
EPLAN macro EDZ / EPLAN Makro EDZEDZ83 KB

Approvals+Certificates: KFD2-GUT-Ex1.D

CertificatesTipo de ArquivoTamanho do Arquivo
China NEPSIPDF2167 KB
China SITIIAS CCC Ex CertificatePDF1074 KB
Europe Pepperl+Fuchs Certificate of Compliance ATEX Category 3PDF198 KB
Europe TUV Nord ATEX Category (1) D ATEX Category (M1) ATEX Category (1) GPDF371 KB
India PESO (India) CCOEPDF84 KB
Korea KOSHAPDF645 KB
South Africa MASCPDF731 KB
TUV Nord IECEx Certificate of ConformityLINK---
United Kingdom CML UK-Type Examination Certificate UKEX Category (1) D UKEX Category (1) G UKEX Category (M1)PDF164 KB
exida Functional Safety AssessmentPDF437 KB
Declaration of Conformity
EU Declaration of Conformity (P+F)PDF188 KB
EU Declaration of Conformity (P+F)PDF183 KB
EU Declaration of Conformity (P+F)PDF181 KB
EU Declaration of Conformity (P+F)PDF183 KB
EU Declaration of Conformity (P+F)PDF179 KB
EU Declaration of Conformity (P+F)PDF180 KB
EU Declaration of Conformity (P+F)PDF181 KB
EU-Konformitäterklärung (P+F)PDF183 KB
EU Declaration of Conformity (P+F)PDF189 KB
EU Declaration of Conformity (P+F)PDF179 KB
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)PDF181 KB
EU Declaration of Conformity (P+F)PDF182 KB
EU Declaration of Conformity (P+F)PDF180 KB
EU Declaration of Conformity (P+F)PDF180 KB
EU Declaration of Conformity (P+F)PDF183 KB
EU Declaration of Conformity (P+F)PDF184 KB
EU Declaration of Conformity (P+F)PDF182 KB
EU Declaration of Conformity (P+F)PDF181 KB
EU Declaration of Conformity (P+F)PDF183 KB
EU Declaration of Conformity (P+F)PDF180 KB
EU Declaration of Conformity (P+F)PDF180 KB
EU Declaration of Conformity (P+F)PDF180 KB
EU Declaration of Conformity (P+F)PDF182 KB

Software: KFD2-GUT-Ex1.D

Device type managers (DTM)Tipo de ArquivoTamanho do Arquivo
DTM Collection Interface Technology 2 / DTM Collection Interface Technology 2ZIP32633 KB
Software Tools
PACTware 4.1 SP6 / PACTware 4.1 SP6ZIP43327 KB
PACTware 5.0 / PACTware 5.0ZIP44203 KB

Produtos Relacionados: KFD2-GUT-Ex1.D

Matching System Components

Interface for Power Rail, Supply current ≤ 4 A, Replaceable fuse, Relay contact output, reversible, LED status indicationpa

35 mm DIN mounting rail with 3-conductor insert, Provides DC supply voltage to all equipped K-System modules, Standard length 2 m (6 foot), simple to customize to application space, Eliminates daisy-chainspa

35 mm DIN mounting rail with 3-conductor insert, Provides DC supply voltage to all equipped K-System modules, Standard length 0.8 m (2.6 ft), simple to customize to application space, Eliminates daisy-chainspa
Device DTM, For K-, E- and H-System, Frame application, like e. g. PACTware, must be installed separatelypa
Universal DTM host platform, For all DTMs of Pepperl+Fuchs, Approved FDT/DTM technology, Free of charge, Download from Pepperl+Fuchs websitepa
Isolated USB interface cable, Used with K-, E- and H-System devices, Used with PACTwarepa
35 mm DIN mounting rail with 3-conductor insert, Provides DC supply voltage to all equipped K-System modules, Standard length 1.6 m (5 foot), simple to customize to application space, Eliminates daisy-chainspa
Cable trunking is integrated in the mounting profile, Safe spacious separation of safe and hazardous signals, No additional cable guides necessary, Standard length 1.8 m (5.8 ft), simple to customize to application space, With mounting aidspa
Cable trunking with integrated Power Rail UPR-03, Safe spacious separation of safe and hazardous signals, No additional cable guides necessary, Provides DC supply voltage to all equipped K-System modules, Standard length 1.8 m (5.8 ft), simple to customize to application space, With end caps UPR-E, cover and mounting aidspa
Accessories

3-pin screw terminal, For KF modules of K-System, Integrated Cold Junction Compensation, Packaging unit: 1 piece, bluepa
1-channel, Precision resistor, Conversion of 0 mA ... 20 mA/0 V ... 5 Vpa
1-channel, Precision resistor, Conversion of 4 mA ... 20 mA/2 V ... 10 Vpa
3-pin screw terminal, For KF modules of K-System, Packaging unit: 5 pieces greenpa
3-pin screw terminal, For KF modules of K-System, Packaging unit: 5 pieces bluepa
Coding of K-System terminal blocks, Coding of LB/FB-System front sockets, Packaging unit: 20 x 6 coding pinspa
Safety Products Selector

Choose from various selection criteria like safety integrity level, performance level, device function, and signal type and find the SIL/PL assessed device that you are looking for.