Inductive sensor NCB40-FP-N0-P1

NCB40-FP-N0-P1
  • 40 mm flush


NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below:

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Folhas de dados: Dados técnicos do  NCB40-FP-N0-P1

General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance40 mm
Installationflush
Assured operating distance0 ... 32 mm
Actual operating distance36 ... 44 mm typ. 40 mm
Reduction factor rAl 0.35
Reduction factor rCu 0.35
Reduction factor r304 0.8
Output type2-wire
Nominal ratings
Nominal voltage8.2 V (Ri approx. 1 kΩ)
Switching frequency0 ... 80 Hz
Hysteresis0 ... 5 typ. 3 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Current consumption
Measuring plate not detected≥ 3 mA
Measuring plate detected≤ 1 mA
Time delay before availability≤ 20 ms
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd2360 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
IECEx approval
Equipment protection level GaIECEx PTB 11.0021X
Equipment protection level GbIECEx PTB 11.0021X
Equipment protection level DaIECEx PTB 11.0021X
Equipment protection level MbIECEx PTB 11.0021X
ATEX approval
Equipment protection level GaPTB 00 ATEX 2032 X
Equipment protection level GbPTB 00 ATEX 2032 X
Equipment protection level DaPTB 00 ATEX 2032 X
UL approvalcULus Listed, General Purpose
Ordinary LocationE87056
Hazardous LocationE501628
Control drawing116-0451
CCC approval
Hazardous Location2020322315002304
NEPSI approval
NEPSI certificateGYJ16.1394X
CML approvalon request
ANZEx19.3001X
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection typescrew terminals
Information for connectionA maximum of two conductors with the same core cross section may be mounted on one terminal connection!
tightening torque 1.2 Nm + 10 %
Core cross sectionup to 2.5 mm2 , stripped insulation length: 7 mm
Minimum core cross-sectionwithout wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2
Maximum core cross-sectionwithout wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2
Connection (system side)screw terminals , M20 x 1.5 cable gland , usable thread length 10 mm , screw-in depth max. 10 mm
Housing materialPBT
Sensing facePBT
Housing basePBT
Degree of protectionIP66 / IP67
Dimensions
Height40 mm
Width83 mm
Length83 mm
General information
Use in the hazardous areasee instruction manuals

Classifications

SystemClasscode
ECLASS 13.027274001
ECLASS 12.027274001
ECLASS 11.027270101
ECLASS 10.0.127270101
ECLASS 9.027270101
ECLASS 8.027270101
ECLASS 5.127270101
ETIM 9.0EC002714
ETIM 8.0EC002714
ETIM 7.0EC002714
ETIM 6.0EC002714
ETIM 5.0EC002714
UNSPSC 12.139121550

Details: NCB40-FP-N0-P1

Datasheet: NCB40-FP-N0-P1

DatasheetTipo de ArquivoTamanho do Arquivo
Datasheet NCB40-FP-N0-P1PDF711 KB
Datasheet NCB40-FP-N0-P1PDF703 KB
Fiche de données NCB40-FP-N0-P1PDF687 KB
Datenblatt NCB40-FP-N0-P1PDF686 KB
Scheda tecnica NCB40-FP-N0-P1PDF706 KB
Datasheet NCB40-FP-N0-P1PDF714 KB
Folha de dados NCB40-FP-N0-P1PDF707 KB
Hoja de datos NCB40-FP-N0-P1PDF687 KB
Datasheet NCB40-FP-N0-P1PDF717 KB

Documents: NCB40-FP-N0-P1

Instruction manualsTipo de ArquivoTamanho do Arquivo
ИнструкцииPDF195 KB
Návod k poużitíPDF188 KB
Instruktions manualPDF186 KB
Instruction manualPDF188 KB
Technical informationPDF158 KB
KasutusjuhendPDF181 KB
KäyttöohjePDF180 KB
Manuel d'instructionsPDF191 KB
BetriebsanleitungPDF187 KB
Technische InformationPDF162 KB
Οδηγίες χρήσηςPDF198 KB
HandleidingPDF187 KB
Instruction manual / BetriebsanleitungPDF185 KB
Használati útmutatóPDF190 KB
Manuale di istruzioniPDF188 KB
Lietošanas pamācībaPDF187 KB
Instrukciju vadovasPDF188 KB
Instrukcja obsługiPDF188 KB
Manual de instruçõesPDF190 KB
Manual de utilizarePDF191 KB
Návod na poużitiePDF188 KB
Navodila za uporaboPDF185 KB
Manual de instruccionesPDF190 KB
ManualPDF185 KB

CAD+CAE: NCB40-FP-N0-P1

CADTipo de ArquivoTamanho do Arquivo
CAD 3-D / CAD 3-DSTP152 KB
CAD Portal / CAD PortalLINK---
EPLAN
CAE EPLAN Data Portal / CAE EPLAN Data PortalLINK---
EPLAN macro EDZ / EPLAN Makro EDZEDZ65 KB

Approvals+Certificates: NCB40-FP-N0-P1

CertificatesTipo de ArquivoTamanho do Arquivo
Australia Test SafePDF6749 KB
Canada USA UL Hazardous LocationPDF412 KB
Canada USA UL Ordinary LocationPDF286 KB
China SITIIAS CCC Ex CertificatePDF3756 KB
EU PTB ATEX ia 2G, 1G, 1D s. certificatePDF12357 KB
Japan CML Ex iaPDF468 KB
United Kingdom CML UKEX Category I M2 UKEX Category II 2 G UKEX Category II 1 D UKEX Category II 1 GPDF420 KB
Worldwide PTB IECEx iaLINK---
Control Drawings
Control drawing UL / Control drawing ULPDF294 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)PDF1248 KB
EU Declaration of Conformity (P+F)PDF1332 KB
EU Declaration of Conformity (P+F)PDF1329 KB
EU Declaration of Conformity (P+F)PDF1327 KB
EU Declaration of Conformity (P+F)PDF1329 KB
UK Declaration of Conformity (P+F)PDF1241 KB
UK Declaration of Conformity (P+F)PDF1303 KB
EU Declaration of Conformity (P+F)PDF1326 KB
EU Declaration of Conformity (P+F)PDF1325 KB
EU Declaration of Conformity (P+F)PDF1326 KB
EU-Konformitäterklärung (P+F)PDF1329 KB
EU Declaration of Conformity (P+F)PDF1333 KB
EU Declaration of Conformity (P+F)PDF1326 KB
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)PDF1327 KB
EU Declaration of Conformity (P+F)PDF1330 KB
EU Declaration of Conformity (P+F)PDF1326 KB
EU Declaration of Conformity (P+F)PDF1327 KB
EU Declaration of Conformity (P+F)PDF1328 KB
EU Declaration of Conformity (P+F)PDF1329 KB
EU Declaration of Conformity (P+F)PDF1327 KB
EU Declaration of Conformity (P+F)PDF1328 KB
EU Declaration of Conformity (P+F)PDF1329 KB
EU Declaration of Conformity (P+F)PDF1327 KB
EU Declaration of Conformity (P+F)PDF1327 KB
EU Declaration of Conformity (P+F)PDF1326 KB
EU Declaration of Conformity (P+F)PDF1329 KB

Produtos Relacionados: NCB40-FP-N0-P1

Accessories

Single-channel terminal amplifier with line breakage detection, input for NAMUR sensors, DC 24 V supply voltage, standardized interface to prevent signal transmission errors, switching state display, LED yellowfa

Our amplify article gives interesting insights about the development of the new, modern portfolio of inductive proximity sensors from Pepperl+Fuchs. Get the whole story here! 

 

 

Knowledge Base for Inductive Sensors

The knowledge base for inductive sensors contains extensive expertise and supports you in the highly precise and smooth operation of the sensors in your machinery and plants.

VariKont com tecnologia Active Shielding

Os sensores indutivos VariKont com tecnologia Active Shielding garantem altas distâncias de comutação, independentemente da situação de instalação e do material circundante. Beneficie-se de um projeto de equipamento mais fácil e de custos reduzidos!

Sensores de segurança indutivos SIL 2 PL d

Como os sensores de segurança indutivos SIL 2/PL d não possuem banda morta, a transferência de dados pode ocorrer sem distância mínima entre o sensor e o alvo. Descubra o portfólio otimizado para ambientes exigentes.