General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance4 mm
Installationflush
Assured operating distance0 ... 3.24 mm
Actual operating distance3.6 ... 4.4 mm typ.
Reduction factor rAl 0.41
Reduction factor rCu 0.39
Reduction factor r304 0.78
Output type2-wire
Nominal ratings
Nominal voltage8.2 V (Ri approx. 1 kΩ)
Switching frequency0 ... 1500 Hz
Hysteresis1 ... 15 typ. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detectedmin. 2.2 mA
Measuring plate detected≤ 1 mA
Switching state indicatorall direction LED, yellow
Functional safety related parameters
Safety Integrity Level (SIL)SIL 2
MTTFd3010 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
IECEx approval
Equipment protection level GaIECEx PTB 11.0037X
Equipment protection level GbIECEx PTB 11.0037X
Equipment protection level DaIECEx PTB 11.0037X
Equipment protection level MbIECEx PTB 11.0037X
ATEX approval
Equipment protection level GaPTB 00 ATEX 2048 X
Equipment protection level GbPTB 00 ATEX 2048 X
Equipment protection level DaPTB 00 ATEX 2048 X
UL approval
Ordinary LocationE87056
Hazardous LocationE501628
Control drawing116-0452
CCC approval
Hazardous Location2020322315002255
NEPSI approval
NEPSI certificateGYJ16.1393X
CML approvalon request
ANZEx18.3018X
Marine approvalDNVGL TAA00001A5
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection typecable
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Degree of protectionIP66 / IP67
Cable
Cable diameter4.8 mm ± 0.2 mm
Bending radius> 10 x cable diameter
MaterialPVC
Core cross section0.34 mm2
Length2 m
Dimensions
Length40 mm
Diameter12 mm
General information
Scope of delivery2 self locking nuts in scope of delivery
Use in the hazardous areasee instruction manuals

Classifications

SystemClasscode
ECLASS 13.027274001
ECLASS 12.027274001
ECLASS 11.027270101
ECLASS 10.0.127270101
ECLASS 9.027270101
ECLASS 8.027270101
ECLASS 5.127270101
ETIM 9.0EC002714
ETIM 8.0EC002714
ETIM 7.0EC002714
ETIM 6.0EC002714
ETIM 5.0EC002714
UNSPSC 12.139121550

Details: NCB4-12GM40-N0

Datasheet: NCB4-12GM40-N0

DatasheetTipo de ArquivoTamanho do Arquivo
Datasheet NCB4-12GM40-N0PDF598 KB
Datasheet NCB4-12GM40-N0PDF594 KB
Fiche de données NCB4-12GM40-N0PDF595 KB
Datenblatt NCB4-12GM40-N0PDF595 KB
Scheda tecnica NCB4-12GM40-N0PDF595 KB
Datasheet NCB4-12GM40-N0PDF601 KB
Folha de dados NCB4-12GM40-N0PDF596 KB
Hoja de datos NCB4-12GM40-N0PDF596 KB
Datasheet NCB4-12GM40-N0PDF607 KB

Documents: NCB4-12GM40-N0

Instruction manualsTipo de ArquivoTamanho do Arquivo
ИнструкцииPDF193 KB
Návod k poużitíPDF184 KB
Instruktions manualPDF184 KB
Instruction manualPDF184 KB
KasutusjuhendPDF177 KB
KäyttöohjePDF176 KB
Manuel d'instructionsPDF188 KB
BetriebsanleitungPDF185 KB
Οδηγίες χρήσηςPDF195 KB
HandleidingPDF185 KB
Instruction manual / BetriebsanleitungPDF182 KB
Használati útmutatóPDF188 KB
Manuale di istruzioniPDF186 KB
Lietošanas pamācībaPDF183 KB
Instrukciju vadovasPDF186 KB
Instrukcja obsługiPDF246 KB
Manual de instruçõesPDF188 KB
Manual de utilizarePDF188 KB
Návod na poużitiePDF186 KB
Navodila za uporaboPDF181 KB
Manual de instruccionesPDF188 KB
ManualPDF181 KB
Technical information
Mounting Instruction locking nut / Montageanleitung, Muttern mit SperrverzahnungPDF1117 KB
Installation conditionsPDF1054 KB
EinbaubedingungenPDF1060 KB

CAD+CAE: NCB4-12GM40-N0

CADTipo de ArquivoTamanho do Arquivo
CAD 3-D / CAD 3-DSTP51 KB
CAD Portal / CAD PortalLINK---
EPLAN
CAE EPLAN Data Portal / CAE EPLAN Data PortalLINK---
EPLAN macro EDZ / EPLAN Makro EDZEDZ65 KB

Produtos Relacionados: NCB4-12GM40-N0

Accessories

Mounting flange, 12 mmfa

Our amplify article gives interesting insights about the development of the new, modern portfolio of inductive proximity sensors from Pepperl+Fuchs. Get the whole story here! 

 

 

Knowledge Base for Inductive Sensors

The knowledge base for inductive sensors contains extensive expertise and supports you in the highly precise and smooth operation of the sensors in your machinery and plants.

VariKont com tecnologia Active Shielding

Os sensores indutivos VariKont com tecnologia Active Shielding garantem altas distâncias de comutação, independentemente da situação de instalação e do material circundante. Beneficie-se de um projeto de equipamento mais fácil e de custos reduzidos!

Sensores de segurança indutivos SIL 2 PL d

Como os sensores de segurança indutivos SIL 2/PL d não possuem banda morta, a transferência de dados pode ocorrer sem distância mínima entre o sensor e o alvo. Descubra o portfólio otimizado para ambientes exigentes.